Home > List of Issue > Table of Contents > Abstract

Journal of Nippon Medical School
Select Language
in Japanese < > in English

Full Text of this Article
in English PDF (68K)

ArticleTitle Effect of the Surface Potential of the Hemodialysis Membrane and the Electrical Charge of the Gadolinium Contrast Medium on Dialyzability
AuthorList Susumu Okada1, Kohei Inoue1, Tetsuji Kijima1, Kiwayo Katagiri2, Tatsuo Kumazaki2
Affiliation 1Department of Radiology, Chiba-Hokuso Hospital, Nippon Medical School 2Department of Radiology, Nippon Medical School
Language EN
Volume 70
Issue 1
Year 2003
Page 12-15
Received July 4, 2002
Accepted August 12, 2002
Keywords hemodialysis, gadolinium contrast medium, membrane potential
Abstract

Purpose: To search for methods of improving the excretion of injected gadolinium contrast medium (GdCM) in hemodialysis (HD) patients, we investigated the effect of the surface potential of HD membranes and the electrical charge of GdCM on the dialyzability of GdCM.
Materials and Methods: Ionic (Gd-DTPA) or non-ionic (Gd-DO3A) GdCM solutions were dialyzed using a clinical HD unit. Two types of HD membranes, AN69 with a surface potential and PMMA without, were used. GdCM clearance was then calculated.
Results: Gd-DTPA clearance was significantly higher for PMMA membranes than for AN69 membranes. Gd-DO3A clearance was slightly higher for AN69 membranes than for PMMA membranes. The difference in Gd-DTPA and Gd-DO3A clearance values was not significant when PMMA membranes were used.
Conclusion: These data indicate that non-ionic GdCM is preferable to ionic GdCM in patients receiving dialysis through an electrically positive membrane. Either ionic or non-ionic GdCM can be used when a normal dialysis membrane is being used.

Correspondence to Susumu Okada, Department of Radiology, Chiba-Hokuso Hospital, Nippon Medical School, 1715 Kamagari, Inba-mura, Inba-gun, Chiba 270-1613, Japan
okada@nms.ac.jp